Features:
Dual GPM/LPM scale printed on both sides of the meter.
1" through 8" pipe sizes.
Flow rateS from 2 to 1900 GPM (8 to 7200 LPM).
Corrosion resistant 316SS or Teflon internal float materials.
One piece machined acrylic body.
Mounts to existing pipe. No unions or adapters required.
Models for mounting on horizontal or vertical pipe.
Mounting clamps and gasket included.
Specifications:
Pipe Requirements: IPS inch pipe size (ASTM-D-1785)
Max. Psi (bar): 150 PSI (10.3 bar) @ 70 F (21 C)
Max. fluid temp.: 190 F (88 C) @ 0 PSI
Max. ambient temp.: 14 to 110 F/ -10 to 43 C
Note: Temperature & Pressure ratings of meter only. Actual pipe rating may vary.
Full scale accuracy: +/- 10%
Power requirement: No power required
Enclosure: NEMA 4X (IP56)
Approximate shipping wt:
1"-4" units: 1 lb. (.45 kg)
6"-8"units: 2 lb. (.91 kg)
Materials of Construction:
Meter Body:Cast Acrylic
Float: Standard range models = 316SS - Low range models = Teflon
Gasket: Neoprene
Pipe Clamp: 300 series Stainless Steel
Pitot screw: 1"thru 2" models only - 300 series stainless Steel
Installation Requirements:
Minimum Straight Pipe Length Requirements - The meter's accuracy is affected by disturbances such as pumps, elbows, tees, valves, etc., in the flow stream. Install the meter in a straight run of pipe as far as possible from any disturbances. The distance required for accuracy is 10 times the nominal pipe diameter before the meter and 4 times the nominal pipe diameter after the meter.
Mounting location:
F series meters must be mounted at the vertical (twelve o'clock) position.
Must be mounted on horizontal pipe only.
U & D series meters must be mounted on vertical pipe only.
The pipe must be completely full of water at all times.
See the minimum straight length of pipe requirement chart above.
The meter can accurately measure flow from one direction only.
U-series meters measure upward flows only.